Pressure transducer with amp. PA-500

 
●To buy this product, please go to the following Online Web stores.
To the Pressure transducer with amp.“PA-500 series” page on the DigiKey online shop

Pressure transducer with amp. PA-500

  • High output gain by built-in hybrid electronic amp.
  • Built-in temperature compensation function (0 ~ 50 °C)
  • Pressure medium compatible with both liquid and gas pressures (Gauge)

Model number designation

PA-500-501D-06

Series name

Rated pressure range

101: 0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2}
5010 ~ 49.0 kPa {0 ~ 0.5 kgf/cm2}
1020 ~ 98.1 kPa {0 ~ 1 kgf/cm2}
3520 ~ 343 kPa {0 ~ 3.5 kgf/cm2}
5020 ~ 490 kPa {0 ~ 5 kgf/cm2}
1030 ~ 981 kPa {0 ~ 10 kgf/cm2}

Pressure reference

GGauge
VGauge (Vacuum)

Thermal error

06± 0.06 % F.S. / °C
10± 0.1 % F.S. / °C

List of model numbers

Model numbersRated pressureMaximum pressureBreak-down pressureThermal errorPressure portCAD
PA-500-101G-10 0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2} 19.6 kPa {0.2 kgf/cm2} 49 kPa {0.5 kgf/cm2} ± 0.1 % F.S./°C R 1/4 (PT 1/4)
PA-500-501G-10 0 ~ 49.0 kPa {0 ~ 0.5} kgf/cm2} 98.1 kPa {1 kgf/cm2} 245 kPa {2.5 kgf/cm2} ± 0.1 % F.S./°C R 1/4 (PT 1/4)
PA-500-501G-06 0 ~ 49.0 kPa {0 ~ 0.5} kgf/cm2} 98.1 kPa {1 kgf/cm2} 245 kPa {2.5 kgf/cm2} ± 0.06 % F.S./°C R 1/4 (PT 1/4)
PA-500-102G-06 0 ~ 98.1 kPa {0 ~ 1} kgf/cm2} 196 kPa {2 kgf/cm2} 490 kPa {5 kgf/cm2} ± 0.06 % F.S./°C R 1/4 (PT 1/4)
PA-500-102G-10 0 ~ 98.1 kPa {0 ~ 1} kgf/cm2} 196 kPa {2 kgf/cm2} 490 kPa {5 kgf/cm2} ± 0.1 % F.S./°C R 1/4 (PT 1/4)
PA-500-352G-10 0 ~ 343 kPa {0 ~ 3.5} kgf/cm2} 686 kPa {7 kgf/cm2} 1030 kPa {10.5 kgf/cm2} ± 0.1 % F.S./°C R 1/4 (PT 1/4)
PA-500-352G-06 0 ~ 343 kPa {0 ~ 3.5} kgf/cm2} 686 kPa {7 kgf/cm2} 1030 kPa {10.5 kgf/cm2} ± 0.06 % F.S./°C R 1/4 (PT 1/4)
PA-500-502G-06 0 ~ 490 kPa {0 ~ 5} kgf/cm2} 981 kPa {10 kgf/cm2} 1471 kPa {15 kgf/cm2} ± 0.06 % F.S./°C R 1/4 (PT 1/4)
PA-500-502G-10 0 ~ 490 kPa {0 ~ 5} kgf/cm2} 981 kPa {10 kgf/cm2} 1471 kPa {15 kgf/cm2} ± 0.1 % F.S./°C R 1/4 (PT 1/4)
PA-500-103G-10 0 ~ 981 kPa {0 ~ 10} kgf/cm2} 1961 kPa {20 kgf/cm2} 2941 kPa {30 kgf/cm2} ± 0.1 % F.S./°C R 1/4 (PT 1/4)
PA-500-103G-06 0 ~ 981 kPa {0 ~ 10} kgf/cm2} 1961 kPa {20 kgf/cm2} 2941 kPa {30 kgf/cm2} ± 0.06 % F.S./°C R 1/4 (PT 1/4)
PA-500-102V-06 0 ~ - 98.1 kPa {0 ~ −1} kgf/cm2} 196 kPa {2 kgf/cm2} 490 kPa {5 kgf/cm2} ± 0.06 % F.S./°C G 1/4 (PF 1/4)
PA-500-102V-10 0 ~ - 98.1 kPa {0 ~ −1} kgf/cm2} 196 kPa {2 kgf/cm2} 490 kPa {5 kgf/cm2} ± 0.1 % F.S./°C G 1/4 (PF 1/4)

Standard specifications

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 V DC.
Pressure reference Gauge、Gauge(Vacuum)
Pressure medium Non-corrosive gases / Non-corrosive liquids
Operating temp. range - 20 ~ 80°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH(No condensation)
Storage temp. - 20 ~ 80 °C(Atmospheric pressure, humidity 65 %RH maximum)
Insulation resistance 100 MΩ minimum (500 VDC)
Dielectric strength 500 V DC, 60 s(Leakage current 1 mA maximum)
Pressure port R1/4 (PT 1/4)、G 1/4 (PT 1/4)
Net weight Approx. 85 g
Supply voltage 12 ~ 24 ± 10 %
Ripple content 10 % (P-P) maximum
Consumption current 20 mA maximum

Analog output

Pressure range101G 501G 102G 352G 502G 103G 102V
Output voltage 1 ~ 5 V
Zero voltage 1 ± 0.04 V (at 25 °C)
Span voltage 4 ± 0.04 V (at 25 °C)
Output current 1 mA max. (Load resistance 5 kΩ min.)
Linearity/Hysteresis ± 0.5 %F.S. ± 0.3 %F.S. ± 0.5 %F.S.
Thermal error/ZERO 
0 ~ 50 °C
(Reference temp.: 25 °C)
± 0.1 %F.S. / °C ± 0.06 / 0.1%F.S. / °C
Thermal error/SPAN
0 ~ 50 °C
(Reference temp.: 25 °C)
± 0.1 %F.S. / °C ± 0.06 / 0.1 %F.S. / °C
Supply voltage effect ± 0.1 V maximum
Response Approx. 1 ms

Environment characteristics

Test itemTest conditions (At 25 ± 5 °C)Permissible change
Vibration 10 ~ 500 Hz, 1.5 mm maximum / 98.1 m/s2,
3 directions for 2 hours each
Zero voltage / Span voltage:
± 1 %F.S. maximum each
Shock 981 m/s2, 3 directions for 3 times each
Pressure cycling 0 ~ Rated pressure, 106 cycles
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs.

Outline dimensions

Internal circuit diagram

●The above contents and descriptions are subject to change without notice. 

Products

×