NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

LIST

×

×


Products

Distributor

US-English

×

Pressure transducer (ratio metric) P-7100

  •  P-7100Fitting: R1/8
    P-7100
    Fitting: R1/8
  •  P-7100Fitting: M5 female
    P-7100
    Fitting: M5 female
  •  P-7100Fitting: R1/8
    P-7100
    Fitting: R1/8
  •  P-7100Fitting: M5 female
    P-7100
    Fitting: M5 female

Contact Us

●To buy this product, please go to the following Online Web stores.
To the Pressure transducer(ratio metric) “P-7100 series” page on the DigiKey online shop
 To the Pressure transducer(ratio metric)  “P-7100 series” page on the Mouser online shop
To the Pressure transducer(ratio metric) “P-7100 series” page on the RS components online shop

Ultra-miniature pressure sensors

  • Suitable for installing inside the narrow space of the equipment thanks to its small size and light weight
    outline dimensions φ 17×18.7mm, Net weight: Approx 19 g (M5 type)
  • High reliability (SUS316L diaphragm, oil-filled) by using double diaphragm structure
  • Supply voltage and analog output is 5±0.5V and the 0.5 ~ 4.5V(ratiometric output)
  • High accuracy by using a digital compensation circuit employing the COB (chip on board) mounting
  • Variety pressure range: 0 ~ 100kPa, -100 ~ 100kPa, 0 ~ 1MPa, 0 ~ 133.3kPa abs

Standard specifications

Media Corrosive gases/liquids compatible with SUS316L and SUS304
Operating temp.range - 20 ~ 70℃
Compensated temp. range 0 ~ 50℃
Operating humidity range 35 ~ 85 %RH(No condensation)
Storage temp. range - 20 ~ 80 ℃(Atmospheric pressure, humidity 65 %RH maximum)
Insulation resistance 100 MΩ minimum(500VDC)
Dielectric strength 500 VAC 60 s(Leakage current 1 mA maximum)
Operating voltage 5 ± 0.5 VDC
Current consumption 3 mA Maximum
Sealed liquid Silicone oil
Net weight R1:Approx.22g, M5:Approx.19g

Analog output

Item/Model number102G103G102R132A
Output voltage※  0.5 ~ 4.5 V   
Output limit  16.5 mV ~ 95 % Vopr   
Zero voltage※  0.5 ± 0.04 V   2.5 ± 0.04 V  0.5 ± 0.1 V
Span voltage※  4.0 ± 0.04 V    4.0 ± 0.1 V
Output current 1 mA Maximum(Load resistance 5kΩ minimum)   
Linearity / Hysteresis ± 0.5 %F.S.   
Thermal error
(Reference temp.25°C)
 Zero / Span : ± 0.05 %F.S. / °C     Zero / Span : ± 0.06 %F.S. / °C  
Response time  Approx. 2ms   
Gravitational
(From horizontal position to vertical position)
 ± 0.3 %F.S.  ± 0.05 %F.S.   ± 0.3 %F.S.   ± 0.3 %F.S.

※Output voltage is proportional to the operating voltage.(ratiometric output)
The resolving power of the analog output is 11 Bits (about 0.002V/0.05%F.S).

Environment Characteristics

Test itemTest conditionsPermissible change
Vibration 10 ~ 500 Hz, 1.5 mm maximum / 98.1m / s2
3 directions for 2 hours each
Analog output (Vzero, Vspan)
± 1 %F.S. maximum each after test
Shock 490 m / s2,3 directions for 3 times each
Pressure cycling 0 ~ Rated pressure, 10cycles
Moisture resistance 40 ℃ 90 ~ 95 %RH 240 hrs.

Model Number Designation

P-7100 -102GR1

Series name

Rated pressure range

102G : 0 ~ 100 kPa
103G : 0 ~  1.0 MPa
102R : - 100 ~ 100 kPa 
132A : 0 ~ 133.3 kPa abs

Pressure reference

G:Gauge (Positive)
R:Gauge (Compound)
A:Absolute

Fitting

R1 : R1/8
M5 : M5 Female

List of model numbers

Model NumberFittingPressure referenceRated pressureMaximum pressureBreak-down pressureCAD
P-7100-102G-R1 R1/8 Gauge 0 ~ 100 kPa 200 kPa 300 kPa
P-7100-102G-M5 M5 Female Gauge 0 ~ 100 kPa 200 kPa 300 kPa
P-7100-102R-R1 R1/8 Gauge - 100 ~ 100 kPa 200 kPa 300 kPa
P-7100-102R-M5 M5 Female Gauge - 100 ~ 100 kPa 200 kPa 300 kPa
P-7100-103G-R1 R1/8 Gauge 0 ~ 1.0 MPa 2.0 MPa 3.0 MPa
P-7100-103G-M5 M5 Female Gauge 0 ~ 1.0 MPa 2.0 MPa 3.0 MPa
P-7100-132A-R1 R1/8 Absolute 0 ~ 133.3 kPa abs 200 kPa abs 300 kPa abs
P-7100-132A-M5 M5 Female Absolute 0 ~ 133.3 kPa abs 200 kPa abs 300 kPa abs

Outline Dimensions

Unless otherwise specified, tolerance : ± 0.5 (Unit: mm)

 

Internal Circuit Diagram

●The above contents and descriptions are subject to change without notice. 

Products

×