Pressure transducer with amp. PA-100
Pressure transducer with amp. PA-100
- Covers low pressure range
- Buit-in a compact amplifier circuit
- Measures differential pressure
Standard specifications
| Pressure reference | Differential ※ 1 |
|---|---|
| Operating temp. range | - 20 ~ 70°C |
| Compensated temp. range | 0 ~ 50 °C |
| Operating humidity | 35 ~ 85 %RH(No condensation) |
| Storage temp. | - 20 ~ 80(Atmospheric pressure, humidity 65 %RH maximum) |
| Pressure medium | Non-corrosive gases |
| Insulation resistance | 100 MΩ Min. (50 VDC) |
| Dielectric strength | 50 VAC, 60 s(Leakage current 1 mA maximum) |
| Pressure port | φ 2.5mm |
| Net weight | Approx. 8g |
| Supply voltage | 5 ± 10 %V DC |
| Consumption current | 5 mA maximum |
※ 1 PA-100- □□□ D-S pressure range Pressure A port − B port = 0 ~ Rated pressure range. PA-100- □□□ D-W pressure range Pressure A port − B port = − Rated pressure range ~ Rated pressure range
Analog output
◆Defined at 5 V of supply voltage.
| Item/ Model number | PA-100 | ||||||
|---|---|---|---|---|---|---|---|
| 100D-S | 200D-S | 500D-S | 100D-W | 200D-W | 500D-W | ||
| Output voltage | 0.5 ~ 4.5 V | ||||||
| Zero voltage ※1 | 0.5 ± 0.08 V | 2.5 ± 0.08 V | |||||
| Span voltage ※1 | 4.0 ± 0.08 V | 2.0 ± 0.08 V | |||||
| Output current | 0.5 mA max.(Load resistance 10 kΩ minimum) | ||||||
| Linearity/Hysteresis | ± 0.5 %F.S. | ||||||
| Response | 5 ms | ||||||
| Gravitational effect (From vertical position to horizontal position) |
- 2 %F.S.max. | -1 %F.S.max. | -0.4 %F.S.max. | -2 %F.S.max. | -1 %F.S.max. | -0.4 %F.S.max. | |
| Thermal error 0 ~ 50 °C (Reference temp.:25 °C) | ZERO | ± 5 %F.S. | ± 3 %F.S. | ± 2 %F.S. | ± 5 %F.S. | ± 3 %F.S. | ± 2%F.S. |
| SPAN | ± 2 %F.S. | ||||||
Model Number Designation
| PA-100- | 100D-S |
|---|---|
|
Series name |
Rated pressure range 100D-S: 0 ~ 1 kPa {102 mmH2O} |
List of model numbers
| Model numbers | Pressure reference※1 | Rated pressure | Maximum pressure | Break-down pressure | CAD |
|---|---|---|---|---|---|
| PA-100-100D-S | Differentia | 0 ~ 1 kPa | 5 kPa | 50 kPa | |
| PA-100-200D-S | Differentia | 0 ~ 2 kPa | 10 kPa | 50 kPa | |
| PA-100-500D-S | Differentia | 0 ~ 5 kPa | 25 kPa | 50 kPa | |
| PA-100-100D-W | Differentia | - 1 ~ 1 kPa | ± 5 kPa | 50 kPa | |
| PA-100-200D-W | Differentia | - 2 ~ 2 kPa | ± 10 kPa | 50 kPa | |
| PA-100-500D-W | Differentia | - 5 ~ 5 kPa | ± 25 kPa | 50 kPa |
Environment Characteristics
| Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
|---|---|---|
| Vibration | 10 ~ 500 Hz, 1.5 mm maximum / 49 m/s2 , 3 directions for 2 hours each |
Zero voltage/Span voltage: ± 2 %F.S. (100D/200D) maximum and ± 1 %F.S. (500D) each |
| Shock | 490 m/s2, 3 directions for 3 times each | |
| Pressure cycling | 0 ~ Rated pressure, 106 cycles | |
| Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs. |
OUTPUT VOLTAGE VS PRESSURE
Outline Dimensions
Internal Circuit Diagram
Documents
- ●The above contents and descriptions are subject to change without notice.