Pressure transducer with amp. PA-100
- ●To make a purchase, contact Distributors, or use e-commerce below.
SALES CHANNEL ;Check our Distributors.- SALES CHANNELClick here to check our Distributors.


Pressure transducer with amp. PA-100
- Covers low pressure range
- Buit-in a compact amplifier circuit
- Measures differential pressure
Standard specifications
| Pressure reference | Differential ※ 1 |
|---|---|
| Operating temp. range | − 20 ~ 70°C |
| Compensated temp. range | 0 ~ 50°C |
| Operating humidity | 35 ~ 85%RH(No condensation) |
| Storage temp. | − 20 ~ 80(Atmospheric pressure, humidity 65 %RH maximum) |
| Pressure medium | Non-corrosive gases |
| Insulation resistance | 100 MΩ Min.(50 V DC) |
| Dielectric strength | 50 V AC, 60 s(Leakage current 1 mA maximum) |
| Pressure port | φ 2.5mm |
| Net weight | Approx. 8g |
| Supply voltage | 5 ± 10 %V DC |
| Consumption current | 5 mA maximum |
※ 1 PA-100- □□□ D-S pressure range Pressure A port − B port = 0 ~ Rated pressure range. PA-100- □□□ D-W pressure range Pressure A port − B port = − Rated pressure range ~ Rated pressure range
Analog output
◆Defined at 5 V of supply voltage.
| Item/ Model number | PA-100 | ||||||
|---|---|---|---|---|---|---|---|
| 100D-S | 200D-S | 500D-S | 100D-W | 200D-W | 500D-W | ||
| Output voltage | 0.5 ~ 4.5V | ||||||
| Zero voltage ※1 | 0.5±0.08V | 2.5±0.08V | |||||
| Span voltage ※1 | 4.0±0.08V | 2.0±0.08V | |||||
| Output current | 0.5mA max.(Load resistance 10 kΩ minimum) | ||||||
| Linearity/Hysteresis | ±0.5%F.S. | ||||||
| Response | 5ms | ||||||
| Gravitational effect (From vertical position to horizontal position) |
-2%F.S.max. | -1%F.S.max. | -0.4%F.S.max. | -2%F.S.max. | -1%F.S.max. | -0.4%F.S.max. | |
| Thermal error 0 ~ 50 °C (Reference temp.:25 °C) | ZERO | ±5%F.S. | ±3%F.S. | ±2%F.S. | ±5%F.S. | ±3%F.S. | ±2%F.S. |
| SPAN | ±2%F.S. | ||||||
Model number designation
| PA-100- | 100D-S |
|---|---|
|
Series name |
Rated pressure range 100D-S: 0 ~ 1 kPa {102 mmH2O} |
List of model numbers
| Model numbers | Pressure reference※1 | Rated pressure | Maximum pressure | Break-down pressure | CAD |
|---|---|---|---|---|---|
| PA-100-100D-S | Differentia | 0 ~ 1kPa | 5kPa | 50kPa | |
| PA-100-200D-S | Differentia | 0 ~ 2kPa | 10kPa | 50kPa | |
| PA-100-500D-S | Differentia | 0 ~ 5kPa | 25kPa | 50kPa | |
| PA-100-100D-W | Differentia | − 1 ~ 1kPa | ± 5kPa | 50kPa | |
| PA-100-200D-W | Differentia | − 2 ~ 2kPa | ± 10kPa | 50kPa | |
| PA-100-500D-W | Differentia | − 5 ~ 5kPa | ± 25kPa | 50kPa |
Environment Characteristics
| Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
|---|---|---|
| Vibration | 10 ~ 500 Hz, 1.5 mm maximum/49 m/s2 , 3 directions for 2 hours each |
Zero voltage/Span voltage: ± 2 %F.S. (100D/200D) maximum and ± 1 %F.S. (500D) each |
| Shock | 490 m/s2, 3 directions for 3 times each | |
| Pressure cycling | 0 ~ Rated pressure, 106 cycles | |
| Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs. |
Output voltage vs pressure
Outline Dimensions
Internal circuit diagram
Documents
- ●The above contents and descriptions are subject to change without notice.