NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

Liste

×

×


Produkte

Verteiler

EU-Deutsch

×

Drehgeber RE20F

 
●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal  Überprüfen Sie die Verteiler.
VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Gehen Sie zum DigiKey Online-Shop.
Gehen Sie zum MOUSER Online-Shop.

COMPACT TWO-PHASE OUTPUT

  • Compact, dia.: 20 mm
  • Low torque, low inertia
  • RoHS compliant

PART NUMBER DESIGNATION

RE20F-100-100

Series name

Resolution (P/R)

100, 300

Output phase

1: “A” only

2“A” & “B” (100 P/R only)

 

 

LIST OF PART NUMBERS

Part number

Output phasesResolutionCAD
RE20F-100-100 “A” only 100 (P/R)
RE20F-300-100 “A” only 300 (P/R)
RE20F-100-200 “A” & “B” 100 (P/R)

ELECTRICAL CHARACTERISTICS

Output phases1 phase “A” only2 phase  “A” & “B”
Photo-sensor maximum current 45 mA maximum (at 25 °C) 
Output wave form Quasi-sinusoidal 
Output phases A A, B
Resolution (P/R) 100, 300 100
Phase difference of outputs A & B ——— 90° ± 45°
Maximum frequency response ——— 12 kHz
Output signal 150 mVp-p minimum ※1  1 Vp-p minimum
Output signal amplitude variation ※2 40 % maximum 
Light source LED 
※ 1 Measured at CP1 in the fig.A of ‘MEASUREMENT CIRCUIT’ on the following page.
※ 2 One phase only : Measured at CP2 in the fig.A of ‘MEASUREMENT CIRCUIT’ on the following page.

MECHANICAL CHARACTERISTICS

Starting torque 0.05 mN·m {0.5 gf·cm} maximum
Inertia  0.2 g·cmmaximum
Shaft loading
(When mounting)
Radial 1.96 N {200 gf} maximum
Axial 4.9 N {500 gf} maximum
Net weight Approx. 15 g
 

ENVIRONMENTAL CHARACTERISTICS

Operating temp. range 0 ~ 50 °C
Storage temp. range - 20 ~ 80 °C
Protection grade IP40

RELIABILITY TEST

Test itemTest conditions
VibrationPower OFF

Amplitude : 1.52 mm or 98.1 m/s2 (10 G) whichever is smaller.
10 ~ 500 Hz excursion 5 min/cycle, 1 hour each for X, Y, Z, directions.

ShockPower OFF 1 time each in 6 directions (X, Y, Z) at 490 m/s2 (50 G), 11 ms.
High temperature
exposure
Power OFF 80 °C  96 h (To be measured after leaving samples for 1 h at normal temperature and humidity after the test.)
Power ON 50 °C  96 h
Low temperature
exposure
Power OFF - 20 °C  96 h
Power ON 0 °C 96 h
HumidityPower OFF 40 °C Relative humidity 90 ~ 95 % 96 h
(To be measured after wiping out moisture and leaving samples for 1 h at normal temperature and humidity after the test.)
Thermal shockPower OFF To be done 10 cycles with the following condition
(To be measured after leaving samples for 1 h at normal temperature and humidity after the test.)
70 °C 1 h、- 20 °C 1 h

OUTPUT

EXTERNAL SCHEMATICS

⦿ 2 phase 100 P/R

INTERNAL CIRCUIT

⦿ 1 phase 100・300 P/R
⦿ 2 phases 100 P/R

MEASUREMENT CIRCUIT

⦿ 1 phase 100・300 P/R
⦿ 2 phases 100 P/R

RATINGS

⦿ LED(at 25 °C)
Maximum current 45 mA
Reverse voltage 4 V
Power dissipation (PD) 75 mW
Temp. derating of PD (25 ~ 60 °C) - 1.4 mW / °C
⦿ Photo-sensor(at 25 °C)
Collector current 20 mA
Collector to emitter voltage (forward) 20 V
Collector to emitter voltage (reverse) 5 V
Collector dissipation (PD) 75 mW
Temp. derating of PD(25 ~ 60 °C) - 1.0 mW / °C

OUTLINE DIMENSIONS

Unless otherwise specified, tolerance: ± 0.4 (Unit: mm)

 

●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.